Welcome To b2b168.com, Join Free | Sign In
中文(简体) |
中文(繁體) |
Francés |Español |Deutsch |Pусский |
| No.13642295
| No.13642295
- Product Categories
- Hoppecke Battery
- Sea-battery
- SORENSEN Battery
- Yuasa Battery
- Panasonic Battery
- Dirk Battery
- US GNB Battery
- MGE Battery
- Germany sunshine battery
- Hercules batteries
- US sea-Battery
- Lead-acid batteries
- French Road Sheng battery
- Gel batteries
- Friendly Links
| Information Name: | Nanjing MGE maintenance and long life battery M2AL12-60 |
| Published: | 2015-01-29 |
| Validity: | 300 |
| Specifications: | Complete |
| Quantity: | 1000.00 |
| Price Description: | |
| Detailed Product Description: | ? MGE MGE agents batteries battery 12V100AH ??quality? MGE battery Note lightning. Lightning is the natural enemy of all appliances must be taken to ensure the effective shielding and grounding protection of UPS. In addition, should the UPS power supply in a place with good ventilation. ??? MGE battery technology experts in science and technology, according to the constant practice applications related to battery UPS power usage, well aware that the main question about the discharge time of UPS configuration tips. ??? After UPS power supply is running on battery energy storage to power the load, the standard of UPS power within itself machine comes with a battery, in general can continue to supply power after a few minutes to a few minutes, but long-term type of UPS is equipped with external battery pack, power outages continue for a long time when the power supply to meet the user's needs, the general long-term type of UPS loaded configuration time up to several hours or more. M2AL 12-60 ≤6.5 18.0 258 166 215 24.0 1450 600 M2AL 12-65 ≤6.0 19.5 350 167 179 22.2 1700 650 M2AL 12-75 ≤5.7 22.5 258 166 215 24.0 1800 700 M2AL 12-80 ≤5.5 24.0 258 166 215 24.0 1900 750 M2AL 12-90 ≤5.2 27.0 306 169 214 30.0 2000 800 M2AL 12-100 ≤4.5 30.0 330 171 222 32.0 2200 900 M2AL 12-120 ≤4.0 36.0 410 176 227 38.0 2400 950 M2AL 12-134R ≤3.8 40.5 342 172 277 42.5 2550 950 M2AL 12-150 ≤3.5 45.0 485 172 240 47.0 2800 1000 M2AL 12-160 ≤3.2 48.0 530 209 240 50.0 2950 1000 M2AL 12-200 ≤3.0 60.0 522 238 223 65.0 3500 1000 MGE battery technology Features : Although the use of maintenance-free battery does not require special maintenance work manually, but when you use or have certain requirements, if used improperly affect battery life. Factors that affect battery life are the following: installation, temperature, charge and discharge current, charging voltage, depth of discharge and long-term charge and the like. 1) The battery installation battery should be installed as far as possible in a clean, cool, ventilated, dry place, and to avoid the sun, radiant heaters or other heat sources influence. The battery should be placed upright, not tilted angle. Between each battery terminal connections firmly. 2) The environment temperature greater impact on the battery, the ambient temperature is too high, the battery will overcharge produce gas, the ambient temperature is too low, the battery will charge less, this will affect battery life. Therefore generally require ambient temperature around 25 ℃, Hills UPS float voltage is set Click temperature. 3) The charge and discharge current of the battery charge and discharge current is generally represented by C, the actual value of C is related to battery capacity. For example in terms of, if it is 100AH ??battery: C = 100A. Panasonic lead-acid maintenance-free battery charging current best about 0.1C, the charging current must not be greater than 0.3C. Charge current is too large or too small will affect battery life. General requirements for the discharge current at 0.05 ~ 3C, UPS in normal use can meet this requirement, but also to prevent the occurrence of unforeseen circumstances, such as a battery short circuit. 4) UPS batteries are charging voltage due to alternate ways of working, under normal circumstances, the mains is charging only when power will be discharged. To extend battery life, Hills UPS charger general by way of constant current limiting control after the battery is fully converted to float state, each section of the float voltage to about 13.7V. If the charging voltage is too high will cause the battery overcharge, otherwise the battery will charge less. Charging voltage is abnormal, it may be a configuration error caused by battery or charger failure caused due, so when installing the battery, be sure to pay attention to the battery size and number of the correctness of different specifications, different batches of batteries do not mix. Do not use inferior charger plus charger and cooling issues to consider when installing. The company promises: Where the company sold products are backed by a 3 year warranty, any quality problems (except for man) I will be replaced free of charge occur within 36 months. At the same time enjoy the company full-time personnel tracking service, on-site installation and commissioning. Free shipping nationwide. Quality and development, we believe in the principle of integrity and respect for everyone? We advocate 'seeking, innovation, collaboration and dedication' spirit? Guarantee. Quality first. A penalty at one hundred ------ sense life? Conscientiously ------? MGE battery products promotional price, comprehensive product (advice, buy, technology, design, location, training, after-sales, etc.) solutions. |
Admin>>>
You are the 15374 visitor
Copyright © GuangDong ICP No. 10089450, Hengxin Technology Co., Ltd. Beijing source All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 15374 visitor
Copyright © GuangDong ICP No. 10089450, Hengxin Technology Co., Ltd. Beijing source All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility

