Welcome To b2b168.com, Join Free | Sign In
中文(简体) |
中文(繁體) |
Francés |Español |Deutsch |Pусский |
| No.13642295
| No.13642295
- Product Categories
- Hoppecke Battery
- Sea-battery
- SORENSEN Battery
- Yuasa Battery
- Panasonic Battery
- Dirk Battery
- US GNB Battery
- MGE Battery
- Germany sunshine battery
- Hercules batteries
- US sea-Battery
- Lead-acid batteries
- French Road Sheng battery
- Gel batteries
- Friendly Links
| Information Name: | US sea-battery HZY12-150 Rates |
| Published: | 2015-03-19 |
| Validity: | 300 |
| Specifications: | Complete |
| Quantity: | 1000.00 |
| Price Description: | |
| Detailed Product Description: | US sea-battery HZY12-150 preferential price "to lead the future Hengxin a source of technology," the company supports the delivery of the country, genuine original, three-year warranty, delivered to your door. Sea-battery Features: 1, patented valve design; so that the exhaust valve has good features. 2. Expansion at the end of the bridge safety design; so the battery life can really play. Expansion of the safety design of the bridge at the end; to extend the role. To extend the role. 3. Special high purity lead batteries, the purity of 99.9999%; full. Special high purity lead batteries, the purity of the full control of the content of impurities in the minimum, the impurity content to a minimum, and it is these impurities cause corrosion of the plate and produce self-discharge of the main reasons. Corrosion and generate self-discharge of the main reasons. 4. The battery separator plate method using shaped package; helps reduce the battery pack shaped bottom plate method;. Battery separators using the shortest path problem S-shaped package board method ministry dendrite or lead shot caused. Ministry of dendrites or short circuit problem caused by lead shot. 5. Opening structural partitions; you can add acid to flow when the electrolyte with the company has a sound service system, operated by battery, UPS, battery chargers, inverters variety, reasonable price, best-selling consumer market, among consumers enjoy a higher status. The purpose of the operation is "professional, service, quality." Service everywhere, trustworthy professional to provide you with the most professional service, 24-hour service time, quality products. This is what we have been pursuing. Customer satisfaction is our driving force. Free 24-hour power shortage rescue, delivery, installation, testing and so on. US sea-battery HZY12-150 advantages: 1. high reserve capacity. 2. No mist discharge. 3. The charge acceptance capacity, high current charge (0.8C-1C). 4. large current discharge, within 8 seconds 30C discharge current, current is not damaged. 5. Ultra-deep discharge, can be used repeatedly to make the discharge, the battery will not be compromised. 6. highly suitable temperature can be used at temperatures of -50 ~ 60 ℃. 7. The self-discharge, completely maintenance free, after fully charged, stored for a year at room temperature can be used. 8. Long life for lead-acid batteries doubled. 9. green pollution-free, renewable after all the materials scrap recycling, pollution-free electrolyte. 10. seismic performance, can be used safely in a variety of harsh environments. 11. not restricted by space, can be placed in any position when in use. 12. Easy to use 13. Because resistance of individual cells, capacity, consistency float voltage, and therefore without a balanced charge. Applications range radio communication system power appliances, medical equipment and instrumentation, uninterruptible power supply UPS office automation systems start shipping locomotives, railway coaches and other portable electrical power control switch lighting, lighting power battery HZY12-150 US sea-battery maintenance and upkeep : In the process of using the UPS system, people often one-sided that the battery is maintenance-free and not take this seriously. However, our data show that the proportion due to battery failure caused by a host failure or UPS is not working properly is about 1/3. Thus, strengthening the proper use and maintenance of the UPS battery to extend battery life and reduce the failure rate of UPS systems, with more and more important. In addition to the optional battery than regular brands, the following aspects should be the proper use and maintenance of batteries: ?? a ?? maintain the proper ambient temperature. Important factors that affect battery life is the ambient temperature, ambient temperature is usually the best battery manufacturers requirement is between 20 ℃ ~ 25 ℃. Although the temperature rise of the battery discharge capacity has increased, but the cost is greatly reduced battery life. According to tests measuring the ambient temperature once more than 25 ℃, every increase of 10 ℃, the battery life would be shortened by half. UPS batteries currently used are generally VRLA batteries, universal design life of five years, which can be achieved in the battery manufacturer demanding environments. Less than the required environmental requirements, there is a great difference in the length of its life. In addition, the increase in ambient temperature can cause the battery internal chemical activity increased, resulting in a lot of heat, in turn prompting the ambient temperature rises, this vicious cycle will shorten battery life ?? accelerate. 2. ???? Regular charge and discharge. UPS power supply system float voltage and discharge voltage at the factory have been commissioning rating, while the size of the discharge increases as the load is increased, the use should be reasonable to adjust the load, such as controlling computers and other electronic equipment The use of several. Under normal circumstances, the load should not exceed 60% UPS rated load. Within this range, the battery does not appear excessive discharge. UPS is connected to the mains due to long-term, high-quality power supply, power outages are rare use of the environment, the battery will be long-term in a floating charge state, a long time will cause the battery to chemical energy and electrical energy into each activity decreased, accelerated aging shorten life. Thus, generally every 2 to 3 months to be completely discharged once, discharge time can be determined based on the battery capacity and load size. After a full load discharge is completed, according to the provisions of more than 8 hours to recharge. Note ????????????? meaning one, no electrolyte leakage under normal use, no cell expansion and rupture. 2, good resistance to shock: fully charged battery completely fixed to 4mm amplitude, frequency 16.7Hz vibration 1 hour, no leakage, no cell expansion and cracking, open circuit voltage is normal. 3, good impact resistance: the battery is fully charged state natural height from 20cm down to 1cm thick hardwood board 3 times. No leakage, no cell expansion and cracking, open circuit voltage is normal. 4, resistance to over-discharge: 25 degrees Celsius, the battery is fully charged state resistance of the discharge given 3 weeks (equivalent resistance of the battery discharge requirements 1CA resistance) to restore the capacity of more than 75%. 5. Good resistance to overcharge: 25 degrees Celsius, a fully charged battery charging status 0.1CA 48 hours, no leakage, no cell expansion and cracking, open circuit voltage is normal, the capacity retention rate of over 95%. 6, resistance to high current: fully charged battery discharge 2CA 5 minutes or 10CA discharge for 5 seconds. No conductive part of the fuse, without the appearance of deformation on a custody. Please note that the temperature should not exceed the range of -20 ℃ ~ + 40 ℃ 2 during storage. The battery must be kept in a fully charged state when the storage battery. Because in transit or during storage due to self-discharge will lose some capacity, please add electricity use. 3. When the long-term storage, to compensate for self-discharge during storage, please add electricity. When custody in excess of 40C conditions have bad impact on battery life, avoid! 4. Do keep in dry and cool, well-ventilated place. UPS battery 5. As in custody or transferred during battery accidentally get wet packing, packaging cartons should be removed immediately to avoid being water wet cardboard box becomes a conductor caused by the positive terminal of the battery discharge or burn. Battery Charger Battery Charger design affects the reliability of UPS batteries very important part of the battery charging conditions have a significant impact on battery life. If the battery has been in a constant or "float" type of electrical charge state, the UPS can be improved to maximize battery life. In fact the life of the battery charge state is much longer than the life of a simple storage conditions. Because the battery charging can delay the natural aging process of the battery, so regardless of running or UPS shutdown state should keep the battery charged. Effect of reliability of the battery cell voltage the battery is a single "primary cells", each of a primary battery voltage of about 2 volts, primary batteries connected in series to form a high-voltage battery, a 12 volt battery composed by six primary batteries, 24-volt battery from a primary battery 12 composed like. When the UPS battery charge, each primary batteries in series have been charged. Original battery performance will lead to some slightly different primary battery charging voltage is higher than other primary battery, the battery will advance this part of aging. As long as a certain concatenated primary battery performance, the performance of the entire cell will also decrease. Test proved battery life and the number of the original series the battery, the battery voltage is higher, the faster aging. UPS UPS battery capacity is constant, the design should be as far as possible so that the battery voltage is low, so the longer the UPS battery life, battery voltage for a certain time, you should choose a small number of voltage primary battery cells in series, do not select the number of the original multi-voltage low The battery cells in series. Some manufacturers UPS's battery voltage is relatively high, because the capacity of a certain time, the higher the voltage, the less current, the wire can be chosen smaller and smaller power semiconductors, thereby reducing the cost of UPS. Capacity 1KVA UPS battery voltage so generally 24ˉ96V. ? Beijing Hai Chi battery sales agent installation: Haidian District, Dongcheng, Xicheng District, Fengtai District, Chaoyang District, Daxing District, Shijingshan District, Mentougou, Fangshan District, Tongzhou District, Shunyi District, Huairou District, Changping District, Pinggu District, Miyun County, Yanqing Yuasa Battery sales agent installation Tianjin:?? Heping District, Hexi District, Hebei District, Hedong District, Nankai District, Hongqiao District, Beichen District, Jinnan District, Wuqing, Xiqing District Baodi District, Dongli District, Jixian, Jinghai County, Ninghe, Tianjin Binhai New Area Shanghai Yuasa Battery Sales Agent installation:? Huangpu, Xuhui, Changning District, Jing'an District, Putuo District, Zhabei District, Yangpu District, Hongkou District, Minhang District, Baoshan District, Jiading District, Pudong New Area, Jinshan District, Songjiang District, Qingpu District, Fengxian District, Chongming County, Chongqing Yuasa Battery Sales Agent installation:? Yuzhong, Dadukou, Jiangbei District, Shapingba District, Jiulongpo, Nan'an District, Beibei District, Shuangqiaoshan area, Yubei, Banan District, Wanzhou, Fuling District, Qianjiang District, Changshou District, Jiangjin, Yongchuan District, Nanchuan District, Qijiang area, Hechuan, Tong County, Tongliang, Dazu County, Rongchang, Bishan County, Dianjiang County, Wulong County, Fengdu County, the city population County, Liangping County, Kai County, Wuxi County, Wushan County, Fengjie County, Yunyang County, Zhong County, pillars Tujia Autonomous County, Pengshui Miao and Tujia Autonomous County, YANG Miao Autonomous County, Xinjiang Uygur Autonomous Region Tujia and Miao Autonomous Yuasa Battery Sales Agent installation:? prefecture-level city - Urumqi, Karamay, Turpan region Hami region, Changji Hui Autonomous Prefecture, Boertala Mongol Autonomous Prefecture, Bayinguoleng Mongol Autonomous Prefecture, Aksu Prefecture, Kirgiz Autonomous Prefecture, Kashi Prefecture, Hotan Prefecture, Ili Kazak Autonomous Prefecture, Tacheng, Altay region 19 counties level cities - Turpan, Hami City, Changji City, Fukang City, Bole, Korla City, Aksu City, Atushi City, Kashi City, the city of Hotan, Yining, Kuitun City, Tower City, Usu City Altay City, Shihezi City, Alar City, Tumxuk, Wujiaqu Tibet Autonomous Yuasa Battery Sales Agent installation:? a prefecture-level city of six regions - Lhasa, Qamdo, Shannan, Xigaze, Nagqu, Ngari, Nyingchi Prefecture, Inner Mongolia sea-battery sales agent is installed? Hohhot, Baotou, Wuhai, Chifeng City, Tongliao, Ordos City, Hulunbeir, Bayannao'er, Wulanchabu, Xilin Gol League, Hing'an, Alashan 11 county-level cities - Holingol, Manzhouli City, Yakeshi, Zhalantun, Root River City, Ergun City, Fengzhen City, Xilinhot City, Erenhot, Ulanhot City, Guangxi Zhuang Autonomous Region Aer City Yuasa Battery Sales Agent installation:?? 14 prefecture-level cities - Nanning, Liuzhou, Guilin, Wuzhou, Beihai, Chongzuo, guests, Hezhou, Yulin, Baise, Hechi, Qinzhou Fangchenggang, Guigang |
Admin>>>
You are the 15374 visitor
Copyright © GuangDong ICP No. 10089450, Hengxin Technology Co., Ltd. Beijing source All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 15374 visitor
Copyright © GuangDong ICP No. 10089450, Hengxin Technology Co., Ltd. Beijing source All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility

